VRC – Electronic Vacuum Switch

VRC_1_8688
VRC_1_8688

Absolute Pressure 1200 to 5 mbar (=hPa), 900 Torr to 1 Torr

The VRC electronic vacuum switch can be used for directly switching a pump or valve in the rough vacuum range. An additional recorder output allows a continuous monitoring of the process pressure.

Benefits

  • Chemically resistant ceramic sensor with Viton sealing (Kalrez sealing on request)
  • Dry relay switch point (switch-over relay)
  • High reliability
  • Excellent reproducibility
  • After detaching the top the switch point is easily adjustable over the whole range by means of a potentiometer
  • Connection by KF small flange or G1/4 female thread
  • Robust metal housing with IP54 protection class

Typical Applications

  • Process automation
  • Plant construction
  • Control of vacuum appliances
  • Operational control of vacuum pumps and plants
  • Additional pump switching
  • Pressure control in the rough vacuum range, e. g. for vacuum furnaces or control and regulation boards
Product Specifications:
  • Measuring Principle Ceramic sensor, piezoresistiv, independent of gas type
  • Materials In Contact With Vacuum Stainless steel 1.4305, Al2O3 Vito , Kalrez on request
  • Measurement Range 1200 – 5 mbar (1050 – 4 Torr), max. overpressure: 4 bar absolute
  • Accuracy +-0.3% full scale
  • Setting Time 20 ms
  • Power Supply 18 – 30 VDC
  • Electrical Connection Phoenix screw terminals
  • Power Consumption
  • Without relay 50 mA, with relay 70 mA
  • Operating Temperature 0…+40C
  • Storage Temperature -10…+60C
  • Recorder Output Actual value 10 mV/mbar, 5 mA
  • Switch Point Set point output 0 – 1.2 V (1 mv / mbar),
  • alternating relay contact 230 V, 5 A,
  • hysteresis 7 mbar (standard, others on request)
  • Vacuum Connection Stainless steel small flange DN 16 ISO-KF, G1/4 female thread
  • Protection Class IP54
  • Weight Approx. 450 g